Download Catalogue
IS 5509:2021 CERTIFIED

Fire Retardant Plywood

IS 5509 certified fire retardant plywood that holds back flame penetration for over 60 minutes, built for hotels, hospitals, offices, schools and any interior where a fire officer has to sign off the materials.

35+

Years of Legacy

5,17,000+

Families Served

16+

States Covered

500+

Authorized Dealers

1,55,00,000+

Premium Plywood sheets Produced

Fire retardant plywood is plywood manufactured and treated to resist ignition and slow the spread of flame. In India it is covered by IS 5509, currently at its third revision dated 2021, and tested by the method in IS 1734 Part 3. A certified board is tested on three separate counts: flame penetration, flammability and rate of burning. Advance Ply publishes all three figures for every fire retardant board it makes. No plywood is fireproof. What these boards buy is time.

What Is Fire Retardant Plywood?

Fire retardant plywood is plywood that has been built to behave differently when fire reaches it. The treatment does not stop the board burning, because wood burns. What it does is push back the moment the board catches, and slow the rate at which flame travels across and through it.

That delay is the entire product. In a building fire, the difference between a surface that ignites in four minutes and one that resists for forty five is the difference between an evacuation that works and one that does not. It is also the difference between a fire contained in one room and a fire that has travelled through the joinery into the corridor.

In India the property is certified under IS 5509. A board carrying that licence has been tested in a laboratory to the method set out in IS 1734 Part 3, and the standard sets thresholds for three distinct behaviours rather than one. This is why a single number quoted as a fire rating is almost always incomplete.

Fire retardant is a separate certification from water performance. A board can be fire retardant and nothing else, as Advance Gold FR is. Or it can carry fire retardant certification alongside marine grade certification under IS 710, as Advance Tungsten and Advance Palladium do. The board edge prints both IS numbers when both apply.

The Advance Ply Fire Retardant Range

Three boards, covering the three situations in which fire performance is specified.

Advance Ply Tungsten Product Specifications

The top of the range. Licensed under IS 710:2024 as marine grade and under IS 5509:2021 as fire retardant, on the same board, with both IS numbers printed on the edge. Thirteen layer hardwood construction, average density 0.78 grams per cubic centimetre, screw holding above 1600 newtons and more than 250 hours of boiling water performance.

SpecificationValue
Indian StandardIS 710:2024 and IS 5509:2021
GradeBWP marine grade with fire retardant certification
Construction13 layer
Core100% Hardwood
Bonding resinPhenol formaldehyde
Formaldehyde emission classE0
DensityAverage 0.78 g/cm³
Moisture content5 to 15 percent
Thickness range6 to 19 mm
Screw holding strengthMore than 1600 N
Resistance to micro-organismsMore than 1700 N
Compressive strengthMore than 6000 N
Boiling water performanceMore than 250 hours
Flame penetrationMore than 60 minutes
FlammabilityMore than 45 minutes
Rate of burningMore than 30 minutes
Modulus of rupture, dry, along the grain (N/mm², average / minimum)49 / 43
Modulus of rupture, dry, across the grain (N/mm², average / minimum)40 / 35
Modulus of elasticity, dry, along the grain (N/mm², average / minimum)6980 / 6359
Modulus of elasticity, dry, across the grain (N/mm², average / minimum)4893 / 4356
Modulus of rupture, wet, along the grain (N/mm², average / minimum)35 / 30
Modulus of rupture, wet, across the grain (N/mm², average / minimum)26 / 23
Modulus of elasticity, wet, along the grain (N/mm², average / minimum)3591 / 3245
Modulus of elasticity, wet, across the grain (N/mm², average / minimum)2678 / 2430
Tensile strength, along the grain50 N/mm²
Tensile strength, across the grain40 N/mm²
Tensile strength, sum of both directions90 N/mm²
Glue shear strength, dry (N, average / minimum)1563 / 1427
Glue shear strength, wet (N, average / minimum)1233 / 1156
Preservative retention12.5 kg per cubic metre
WarrantyLifetime

It is also the only board in the range carrying an E0 formaldehyde emission class, the lowest offered. For a hospital ward, a hotel guest room or a nursery, where the board sits behind closed shutters in an enclosed space, that matters as much as the fire figures. Lifetime warranty.

Advance Ply Palladium Product Specifications

The same two certifications, IS 710:2024 and IS 5509:2021, at an E1 emission class. Average density 0.75, screw holding above 1600 newtons, boiling water proof, and the highest wet glue shear strength in the fire retardant range at 1310 newtons average. Thirty six year warranty.

SpecificationValue
Indian StandardIS 710:2024 and IS 5509:2021
GradeBWP marine grade with fire retardant certification
Core100% Hardwood
Bonding resinPhenol formaldehyde
Formaldehyde emission classE1
DensityAverage 0.75 g/cm³
Moisture content5 to 15 percent
Thickness range6 to 19 mm
Screw holding strengthMore than 1600 N
Resistance to micro-organismsMore than 1700 N
Compressive strengthMore than 5500 N
Boiling water performanceBoiling water proof
Flame penetrationMore than 60 minutes
FlammabilityMore than 45 minutes
Rate of burningMore than 30 minutes
Modulus of rupture, dry, along the grain (N/mm², average / minimum)49 / 43
Modulus of rupture, dry, across the grain (N/mm², average / minimum)40 / 36
Modulus of elasticity, dry, along the grain (N/mm², average / minimum)6589 / 6036
Modulus of elasticity, dry, across the grain (N/mm², average / minimum)4890 / 4352
Modulus of rupture, wet, along the grain (N/mm², average / minimum)27 / 25
Modulus of rupture, wet, across the grain (N/mm², average / minimum)22 / 20
Modulus of elasticity, wet, along the grain (N/mm², average / minimum)3456 / 3289
Modulus of elasticity, wet, across the grain (N/mm², average / minimum)2564 / 2340
Tensile strength, along the grain48 N/mm²
Tensile strength, across the grain38 N/mm²
Tensile strength, sum of both directions86 N/mm²
Glue shear strength, dry (N, average / minimum)1456 / 1348
Glue shear strength, wet (N, average / minimum)1310 / 1236
Preservative retention12.5 kg per cubic metre
Warranty36 years

This is the specification for commercial interiors where fire performance and water exposure both apply and the project does not specifically call for E0.

Advance Ply Gold FR Product Specifications

Fire performance for dry interiors. Licensed under IS 5509:2021, eleven layer construction in 19 mm, average density 0.68, screw holding above 1500 newtons and more than 100 hours of boiling water performance. Thirty year warranty.

SpecificationValue
Indian StandardIS 5509:2021
GradeFire retardant
Construction11 layer in 19 mm
Bonding resinPhenol formaldehyde with fire retardant treatment
Formaldehyde emission classE1
DensityAverage 0.68 g/cm³
Moisture content5 to 15 percent
Thickness range6 to 19 mm
Screw holding strengthMore than 1500 N
Compressive strengthMore than 5500 N
Boiling water performanceMore than 100 hours
Flame penetrationMore than 60 minutes
FlammabilityMore than 45 minutes
Rate of burningMore than 30 minutes
Modulus of rupture, dry, along the grain (N/mm², average / minimum)40 / 37
Modulus of rupture, dry, across the grain (N/mm², average / minimum)29 / 25
Modulus of elasticity, dry, along the grain (N/mm², average / minimum)4656 / 4050
Modulus of elasticity, dry, across the grain (N/mm², average / minimum)3258 / 3089
Glue shear strength, dry (N, average / minimum)1203 / 1126
Glue shear strength, wet (N, average / minimum)1029 / 959
Preservative treatmentSurface treatment
Warranty30 years

Specify it where the requirement is fire retardancy and the board will not face standing water. For a hotel corridor panel or an office cabin, this is the board. For a commercial kitchen, move up to Tungsten or Palladium.

Compare the Three Advance Ply Fire Retardant Grades

SpecificationAdvance TungstenAdvance PalladiumAdvance Gold FR
StandardIS 710:2024 and IS 5509:2021IS 710:2024 and IS 5509:2021IS 5509:2021
GradeBWP marine and FRBWP marine and FRFR
Emission classE0E1E1
Average density (g/cm³)0.780.750.68
Screw holdingMore than 1600 NMore than 1600 NMore than 1500 N
Flame penetrationMore than 60 minutesMore than 60 minutesMore than 60 minutes
FlammabilityMore than 45 minutesMore than 45 minutesMore than 45 minutes
Rate of burningMore than 30 minutesMore than 30 minutesMore than 30 minutes
Boiling waterMore than 250 hoursBoiling water proofMore than 100 hours
Glue shear, wet (N), average / minimum1233 / 11561310 / 12361029 / 959
Compressive strengthMore than 6000 NMore than 5500 NMore than 5500 N
Preservative retention12.5 kg per cubic metre12.5 kg per cubic metreSurface treatment
WarrantyLifetime36 years30 years
Specify it whenThe board faces fire risk and water together, and indoor air matters mostThe board faces fire risk and water together in a residential or commercial interiorThe requirement is fire performance in a dry interior

What the Three Fire Test Figures Actually Mean?

This is the part that decides whether you are comparing boards or comparing marketing. IS 5509 does not produce one fire rating. It produces three, and they measure different things.

TestAdvance Ply rangeWhat it measures
Flame penetrationMore than 60 minutesHow long a flame takes to burn right through the board from one face to the other. This is the figure that matters for a partition or a door, because it governs how long the board holds the fire on one side of it.
FlammabilityMore than 45 minutesHow long the board resists sustaining a flame of its own once a flame is held against it. This governs how readily the surface itself becomes part of the fire rather than just fuel sitting next to it.
Rate of burningMore than 30 minutesHow long the board takes to be consumed under the test conditions. This is the slowest of the three thresholds and the one most often quoted on its own, which is why figures from different brands so rarely compare.
Why brand comparisons on this subject are usually meaningless: Walk the market and you will find one brand publishing 90 minutes, another publishing more than 30 minutes, and a third publishing a formula based on thickness. None of them says which of the three tests the number came from. A 90 minute flammability figure and a 30 minute rate of burning figure describe completely different properties, and neither is better than the other in the abstract. Before you compare any two boards, ask both suppliers the same question: which test is this number from, and what are the other two? The supplier who can answer has tested the board. The supplier who cannot has quoted a brochure.

There is a fourth question worth asking, which no figure on any sheet answers: where does the retardant chemistry sit. A coating on the surface and chemistry built into the glue line behave identically on day one and very differently after the board has been cut, routed, sanded and lived with for ten years.

IS 5509 and IS 710 on the Same Fire Retardant Plywood Board

Two standards, two separate licences, one board. IS 710:2024 certifies marine grade boiling water performance with mandatory preservative treatment. IS 5509:2021 certifies fire retardant performance. They test different properties and neither implies the other.

IS 5509 Fire retardant grade
IS 710 Boiling Water Proof marine grade

Advance Ply Tungsten and Advance Ply Palladium hold both. The board edge prints both IS numbers alongside the ISI mark and the BIS licence number, and the specification sheet carries both sets of figures.

Where that combination gets specified

  • Commercial kitchens: Heat, steam, standing water and a fire risk that is part of the daily operation rather than an accident.
  • Hotel bathrooms and wet areas: Fire approval covers the whole guest room, and the vanity unit sits in standing water.
  • Hospital utility and sluice rooms: Washed down daily, inside a building where evacuation is slow.
  • Coastal commercial projects Salt laden humidity attacks the board continuously while the fire requirement still applies.
  • Laboratory and pantry joinery Water at the sink, heat at the bench, and an institutional fire specification over both.
For specification writers, the line to use is

IS 5509:2021 and IS 710:2024 certified plywood, phenol formaldehyde bonded, 100% hardwood construction, CCB preservative treated.


Where only one of the two applies, specify only the one you need. A dry office cabin does not need marine grade, and Advance Gold FR is the board written for that case.

Where Fire Retardant Plywood is Used?

Hotels and hospitality

Guest room wardrobes, corridor panelling, reception joinery and back of house storage. Fire and life safety approval for a hotel interior is usually where the fire retardant requirement first appears in writing. The same specification usually covers the flush door shutters alongside the panel boards, under their own standard.

Hospitals and healthcare

Ward furniture, nurse stations, storage units and partition infill. Evacuating a hospital is slower than evacuating an office, which is why the delay these boards buy matters more here than almost anywhere else.

Schools, colleges and hostels

Classroom storage, laboratory furniture, library joinery and hostel wardrobes. Occupancy is dense and young, and escape routes must stay usable.

Offices and commercial interiors

Workstation cores, cabin panelling, server room joinery and pantry units. Many corporate fit out specifications now name fire retardant plywood by default for anything built into the shell.

Malls, cinemas and assembly spaces

Any enclosed space where a large number of people are seated or moving through, and where internal finishes decide how fast flame spreads across a surface.

Commercial kitchens and utility areas

Where heat and water are both present. This is the case for the two boards that carry IS 710 and IS 5509 together rather than fire performance alone.

Residential interiors

Kitchens, false ceilings and built in wardrobes in high rise apartments, where a fire in one unit must not spread through the joinery of the next.

How to Check Whether Fire Retardant Plywood Is Genuine?

Five checks, in the order worth doing them. The first one takes ten seconds and settles most cases.

  1. Read the IS number and the edition year on the board edge

    A fire retardant board carries IS 5509 printed on the edge with the ISI mark and a BIS licence number. If the edge prints only IS 303 or IS 710, the board is not licensed as fire retardant, whatever the brochure says.

  2. Ask for the technical specification sheet for that exact board

    Not a brand brochure. The sheet should name the product, the standard with its edition year, the BIS licence number and all three fire figures. Every Advance Ply board carries a QR code that opens its own sheet.

  3. Check that all three fire figures are published, not one

    A single number quoted without naming its test tells you nothing. Flame penetration, flammability and rate of burning are three separate tests with three separate thresholds.

  4. Confirm the treatment is factory applied, not site applied

    A fire retardant paint brushed on after installation is a different product with a different life. Ask whether the retardant chemistry sits in the glue line and under the press, or in a tin.

  5. Collect the warranty certificate at the point of purchase

    A warranty that is never issued is not a warranty. Ask for it in writing against the invoice, with the product name on it.


The same procedure applies to any board, and on a fire retardant board the edition year matters as much as the IS number, because IS 5509 has no 2024 edition. The full version is in our guide to the six markings and the BIS Care app check, including what to do when a licence number does not resolve.

Which Thickness to Specify?

The Advance Ply fire retardant range runs from 6 to 19 mm, in 8 by 4, 7 by 4, 6 by 4, 8 by 3, 7 by 3 and 6 by 3 foot sheets.

ApplicationThicknessWhy
Wardrobe and storage carcass18 or 19 mmCarries the load and holds hinges and runners over years of use
Shutters18 mmStays flat over a full height shutter and takes hinge screws reliably
Cabin and corridor panelling12 to 18 mmThickness here affects how long the panel takes to burn through, so review it against the fire specification
Back panels and drawer bottoms6 to 12 mmDepends on span. A long unsupported back panel needs the thicker end
False ceiling framing infill12 mmLight enough to handle overhead, thick enough to hold fixings

A note on back panels in a fire rated assembly

A 6 mm back panel will burn through faster than the 19 mm carcass around it. On a project where the joinery is part of a fire strategy rather than just furniture, that thin panel is the weak point, and it is worth raising with the consultant before the cutting list is issued. Fire does not read the specification, it finds the thinnest section.

What IS 5509 Certification Actually Requires?

IS 5509 is the Indian Standard for fire retardant plywood. It sits at its third revision, dated 2021. The second revision was dated 2000, and that is the edition most freely available online on this subject is working from a superseded document.

Certification is not a self declaration. It is a BIS licence held by a manufacturer for a specific product, tested in a laboratory, and it carries a licence number. The licence number is printed on the board alongside the ISI mark. A board without that marking is not certified, whatever the brochure, the invoice or the dealer says.

The fire tests are performed by the method set out in IS 1734 Part 3, which is the test methods standard for plywood and other wood based panels. That is why specification sheets cite IS 5509 for the product and IS 1734 for the method.

Current edition IS 5509:2021 Third revision. There is no 2024 edition.
What proves it BIS licence number Printed on the board beside the ISI mark, not on the brochure.
Test method IS 1734 Part 3 The method all three fire figures are measured by.
Check the edition year on anything you are handed: IS 5509 has no 2024 edition. If a brochure, a sheet or a competitor page cites IS 5509:2024, the citation is wrong. The current edition is 2021. For completeness on the other standards that appear alongside it: IS 303 is at its 2024 fourth revision, IS 710 at its 2024 third revision, IS 1659 for block boards remains at 2004, and IS 2202 for flush doors sits at Part 1:2023 and Part 2:2022.

Is Fire Retardant the Same as Fireproof?

No. Fire retardant means the board resists ignition and slows flame spread for a measured period. Fireproof would mean the board does not burn, and no plywood meets that description, because plywood is wood.

Fire retardant means

The board resists ignition and slows flame spread for a measured period, tested in a laboratory and stated in minutes.

Fireproof would mean

The board does not burn at all. No plywood meets that description, because plywood is wood.

This distinction is not pedantry. It decides what you can put in a fire approval submission. A consultant or fire officer assessing an interior wants a tested figure in minutes against a named standard. A claim that a board is one hundred percent fire proof supplies neither, and a submission built on that claim can be rejected after the joinery has already been fabricated.

The honest version of the claim is the useful one. These boards buy time.

60+ minutes before flame penetrates the board
45+ minutes before the board sustains a flame of its own
30+ minutes before the board is consumed

Those are numbers a fire strategy can be built on.

Factory Treated Versus Site Applied Fire Retardant

There are two ways to get fire performance into an interior, and they are not equivalent.

Factory treated boardSite applied coating
What it isRetardant chemistry introduced during manufacture, under heat and pressA paint or varnish applied to ordinary plywood after installation
CertificationA BIS licence under IS 5509, with a number printed on the boardNone. The coating may be tested, the board is not
Where it sitsThrough the board, including the glue lineOn the surface only
After cuttingExposed edges behave consistently with the rest of the boardEvery cut exposes untreated core
Over timeStays as manufactured for the life of the boardWears, washes and sands away. Needs reapplication
In a submissionLicence number satisfies the reviewerUsually challenged

A coating has its uses, particularly on existing joinery that cannot be replaced. It is not a substitute for a certified board on new work, and presenting it as one is the mistake that gets a fit out sent back.

Common Mistakes When Buying Fire Retardant Plywood

Treating fire retardant as fireproof

No plywood is fireproof. These boards delay ignition and slow flame spread, which buys evacuation time and limits spread between compartments. A brand that claims a board is one hundred percent fire proof, or gives no figure in minutes at all, is making a claim it cannot support under test.

Quoting one fire figure from one brand against a different figure from another

Flame penetration, flammability and rate of burning are three different tests. Comparing a 90 minute claim from one brand against a 30 minute figure from another, without knowing which test each came from, is not a comparison at all.

Assuming a fire retardant board is also water resistant

It is not, unless the edge says so. Advance Gold FR is licensed under IS 5509 alone. Advance Tungsten and Advance Palladium carry IS 710 as well, which is what makes them suitable where heat and water are both present.

Specifying fire retardant for the shutters and ordinary plywood for the carcass

Fire does not read the specification. If the carcass behind the shutter is untreated, the assembly performs to the weaker of the two.

Applying a fire retardant coating to ordinary plywood and calling it compliant

A site applied coating is not an IS 5509 licence. It may help, but it does not make the board a certified fire retardant board, and a fire officer reviewing the submission will ask for the licence number.

Ignoring the edges and cut outs

Every cut exposes untreated core on a surface treated board. On boards where the retardant chemistry sits in the glue line, this matters less, which is a question worth asking before you cut.

Handling and Installation Notes

Store flat, off the floor and away from damp

Stacked flat on battens, not leaning against a wall. A bowed sheet never comes back straight and will fight every fixing you put into it.

Acclimatise for 48 hours before fabrication

Let the board settle to the humidity of the space it will live in. The published moisture content window is 5 to 15 percent, and the board should be inside that window when you cut it, not when it left the factory.

Seal cut edges and cut outs

Particularly on boards where the fire retardant treatment is applied to the surface. Sealing also keeps the edge clean under laminate.

Keep the ISI marked edge visible where you can

On concealed carcass work, photograph the edge marking before the board is cut. Fire approval submissions ask for proof, and a photograph of the marking next to the invoice is the easiest proof there is.

Do not over sand the face

On a surface treated board, aggressive sanding removes part of what you paid for. Clean and key the surface, do not strip it.

Use the warranty certificate as a project document

File it with the handover pack. For a hotel or hospital project the facility team will be asked for it years later.

Why Specifiers Choose Advance Ply?

Three reasons that hold up when a consultant asks for evidence rather than a brochure.

All three fire figures are published, per board

Flame penetration, flammability and rate of burning, labelled, on the specification sheet for each product, with the edition year of the standard stated.

Two standards on one board where the application needs both

Advance Tungsten and Advance Palladium carry IS 710:2024 and IS 5509:2021 together, with both IS numbers on the edge, so a commercial kitchen or a hotel wet area is covered by one specification rather than two.

The sheet is reachable from the board itself

Every Advance Ply board carries a QR code that opens the technical specification sheet for that exact product, with the BIS licence number on it. A specifier standing in front of a stack can verify it without calling anybody.

Advance Ply has manufactured plywood, block boards and flush doors since 1991, and the fire retardant range sits alongside a full set of marine, BWP, BWR and MR grade boards under the same quality system.

Advance Ply Fire Retardant Plywood

Specifying Fire Retardant Plywood For A Project?

If your project has a fire approval requirement, the question to settle before anything is ordered is simple: which board, under which standard, with which figures.

Advance Ply publishes all three fire figures for all three of its fire retardant boards, with the edition year stated and the licence number on the board. Ask any other supplier for the same, and the shortlist will make itself.

Frequently Asked Questions About Fire Retardant Plywood

How long does fire retardant plywood resist fire?

It depends which test you mean, which is why a single number quoted on its own is misleading. On the Advance Ply fire retardant range, flame penetration is more than 60 minutes, flammability more than 45 minutes and rate of burning more than 30 minutes. Before comparing any brand against another, ask which of the three tests their number came from.

You can improve its behaviour, but you cannot make it a certified fire retardant board. IS 5509 is a licence held by a manufacturer for a tested product, not a property you add afterwards. A fire officer reviewing a submission will ask for the BIS licence number on the board, and a tin of coating does not supply one.

That depends entirely on where the retardant chemistry sits. A coating brushed on at site wears, washes and sands away. Chemistry built into the board during manufacture, under heat and press, stays where it is for the life of the board. This is the single most useful question to ask a supplier, and the answer should be in writing on the specification sheet rather than given verbally.

The National Building Code governs fire and life safety for internal finishes, and the requirement bites hardest in institutional, assembly and high rise occupancies. In practice the requirement usually appears during the fire approval process for hotels, hospitals, schools, offices, malls and cinemas, and increasingly in high rise residential specifications. Your local fire officer and the project consultant decide what is acceptable, so get the requirement in writing before the joinery is ordered.

Not when the board is manufactured as a fire retardant product rather than treated afterwards. Advance Gold FR publishes a dry modulus of rupture of 40 along the grain and screw holding above 1500 N. Advance Tungsten, which is fire retardant and marine grade together, publishes 49 and above 1600 N. Those figures sit alongside the fire figures on the same sheet, which is the point of asking for the sheet.

Check the formaldehyde emission class, which is a separate matter from fire performance. Advance Tungsten carries E0, the lowest class in the Advance Ply range. Advance Palladium and Advance Gold FR carry E1, which is suitable for enclosed residential and commercial interiors. For a hospital ward or a hotel guest room, the emission class is worth reading before the fire figures.

Yes. It takes laminate, veneer, paint and polish the same way as any other quality plywood. Bear in mind that the finish applied over it has its own fire behaviour, and on a project where surface spread of flame is being assessed, the finish may be reviewed alongside the substrate.

Advance Tungsten carries a lifetime warranty. Advance Palladium carries 36 years. Advance Gold FR carries 30 years. Collect the warranty certificate at the point of purchase, with the product name written on it against the invoice, and file it with the project handover documents.

Evaluating different brands? Compare the top 10 plywood brands in India.

Advance Ply Fire Retardant Plywood | IS 5509:2021 Certified

60+ Min Flame Penetration | 45+ Min Flammability | 30+ Min Rate of Burning | NAFRG Technology

Fill the form for Quick Enquiry

Got something on your mind? Reach out and let’s connect. We’re always here to listen, help, and make things happen.