Download Catalogue

Advance Ply
Gold FR

Available in

Lightweight fire-rated panelling and cladding

Partition panels and thin fire-rated applications

Internal shelving in fire-compliant spaces

Fire-rated door carcasses and lightweight structural panels

Standard commercial furniture carcass in fire-regulated buildings

Standard: 8×4 ft  |  Also available: 7×4, 6×4, 8×3, 7×3, 6×3 ft

Advance Ply Gold FR Logo Fire Retardant IS 5509 Certified Plywood

Advance Ply Gold FR is IS 5509 certified fire retardant plywood with IS 303 boiling water resistant (BWR) grade performance. It is specifically manufactured for projects where fire safety compliance is a regulatory or contractual requirement.

Gold FR is specified by architects for hotels, hospitals, schools, shopping malls, corporate offices, high-rise residential buildings, and any commercial space governed by Indian fire safety regulations. It resists flame penetration and delays the spread of fire, providing additional evacuation time in the event of a fire.

Every Gold FR sheet is manufactured with Nano Alumina treatment and Nano Flame Guard coating, combined with HEXAPRO technology for structural strength and dual CCB chemical treatment for life-long termite and borer protection.

Our technology

Why Advance Ply Gold FR Meets The Fire Safety Standards Your Project Requires?

60+

Min Flame Resistance

IS 5509 certified. Flame penetration resistance above 60 minutes. Provides additional evacuation time in the event of a fire in hotels, hospitals, schools, and high-rise buildings.

IS 5509

Fire Retardant

IS 5509 certification from the Bureau of Indian Standards confirms the product meets the national standard for fire retardant plywood. Required for building regulation compliance in commercial projects.

IS 303

BWR Certified

IS 303:2024 certified boiling water resistant grade. Suitable for humid indoor environments in addition to fire-safety-critical applications.

4x

Hydraulic Pressing

HEXAPRO technology presses each sheet 4 times under hydraulic pressure for maximum density and structural strength alongside fire retardant performance.

2x

CCB Treatment

Dual Copper-Chrome-Boron treatment for life-long termite and borer protection throughout the full sheet thickness.

Nano

Fire Treatment

Nano Alumina treatment + Nano Flame Guard full-surface coating. The fire retardant treatment is internal not a surface wash that can degrade over time.

Where to use

Recommended Applications for Advance Ply Gold FR

hotel

Hotels and Hospitality

All woodwork in hotels, resorts, and serviced apartments where fire safety compliance is mandatory. IS 5509 certification required.

hospital

Hospitals and Healthcare

Patient rooms, corridors, nurse stations, reception furniture. Fire retardant and IS 303 BWR grade for hygiene-compatible spaces.

school

Schools and Educational Buildings

Classroom furniture, library shelving, corridor panelling. IS 5509 compliance for government and private educational buildings.

mall

Shopping Malls and Retail

Shop fit-outs, display fixtures, retail counters. Fire regulations for commercial spaces with high occupancy.

corporate office

Corporate Offices

Workstations, meeting room panelling, reception areas in high-rise commercial buildings requiring fire-safe specification.

high-rise residential

High-Rise Residential

Apartment interiors in buildings above 15 metres where fire safety regulations specify fire retardant materials for furniture and joinery.

Technical Data

Advance Ply Gold FR - Technical Specifications

Specification

Value

Physical Properties

Plywood typeFire Retardant Grade Plywood
IS standardIS 5509:2024
Core construction100% Hardwood, 11-Layer Construction (19mm)
DensityAvg 0.68 g/cm³
Thickness range6mm, 9mm, 12mm, 16mm, 19mm
Standard sheet sizes8x4 ft, 7x4 ft, 6x4 ft, 8x3 ft, 7x3 ft, 6x3 ft
CalibratedYes, calibrated with 4-time pressing
Moisture content5%–15% (Oven Dry Method)

Chemical Properties

Resin typeE1 Grade Phenol Formaldehyde Resin
Formaldehyde emissionE1 Grade (Low Formaldehyde Emission)
Preservative treatmentSurface treatment for termite, borer, fungus and fire-retardant chemicals
Nano Alumina TreatmentImproves fire resistance performance
Nano Flame Guard CoatingExtra surface protection against flame spread

Mechanical Properties

Screw holding capacityMore than 1500N
Modulus of elasticity (dry) Along grain: Avg 4,656 N/mm², Min 4,050 N/mm²
Across grain: Avg 3,258 N/mm², Min 3,089 N/mm²
Modulus of rupture (dry) Along grain: Avg 40 N/mm², Min 37 N/mm²
Across grain: Avg 29 N/mm², Min 25 N/mm²
Glue shear strength (dry)Avg 1,203 N/mm², Min 1,126 N/mm²
Glue shear strength (wet)Avg 1,029 N/mm², Min 959 N/mm²
Compressive strengthMore than 5500 N

Fire and Water Resistance

Boiling water resistanceUp to 100 Hours
Flame penetration resistanceMore than 60 Minutes
Flammability resistanceMore than 45 Minutes
Rate of burning resistanceMore than 30 Minutes
Fire retardant certificationIS 5509:2024 Certified

Manufacturing

Press cycles4x Hydraulic Pressing using HVRT Technology and HEXAPRO Process
Core material100% Hardwood Tropical Species
CalibrationArchitectural Grade Calibration

Warranty

Warranty30 Years Manufacturer Warranty
Compare grades

Advance Ply Gold FR vs Other Advance Ply Plywood Range

FeatureGold FR (this)TungstenGold
IS standardIIS 5509:2024IS 710:2024 + IS 5509:2024IS 303:2024
Grade typeFire Retardant GradeBWP Marine Grade + Fire RetardantBWR Grade
E1 Grade ResinYesNo (EO Grade Resin)Yes
Fire retardant (IS 5509)YesYesNo
Density0.68 g/cm³0.78 g/cm³0.75 g/cm³
Warranty30 YearLifetime30 Year
Boiling Water ResistanceUp to 100 HoursMore than 250 HoursMore than 200 Hours
Core Construction11-Layer Hardwood (19mm)13-Layer HardwoodHardwood Core
Best forHotels, hospitals, schools, commercial buildings and interiors requiring fire safety complianceModular kitchens, bathrooms, marine applications, hotels, hospitals and fire-compliance projectsGeneral furniture, wardrobes, cabinets, partitions and moisture-prone interiors
FAQ

Frequently Asked Questions About Advance Ply Gold FR

Where is Advance Ply Gold FR fire retardant plywood required?

Gold FR is required in any building or space governed by fire safety regulations: hotels, hospitals, schools, shopping malls, corporate offices, high-rise residential buildings, and public buildings. Check the applicable National Building Code and local fire safety authority requirements for specific compliance documentation needed.

Advance Ply Gold FR carries IS 5509 certification for fire retardancy and IS 303 certification for boiling water resistant (BWR) grade plywood. IS 5509 is the Bureau of Indian Standards specification for fire retardant plywood and verifies resistance to flame penetration above 60 minutes.

Both Gold FR and Tungsten carry IS 5509 fire retardant certification. Tungsten additionally carries IS 710 boiling waterproof (BWP) certification for kitchens, bathrooms, and marine use. Gold FR is IS 303 BWR grade – suitable for dry commercial spaces requiring fire compliance. For applications requiring both BWP waterproofing and fire retardancy, specify Tungsten.

Yes. IS 5509 certification from the Bureau of Indian Standards is the recognised standard for fire retardant plywood in India. Certification documentation is available on request for government procurement, institutional projects, and contractor compliance submissions. Call 18002033359.

No. The fire retardant treatment in Gold FR is internal applied through Nano Alumina treatment and Nano Flame Guard coating during manufacturing not a surface application that can wash away. The certification applies throughout the product life under normal indoor conditions.

Advance Ply Gold FR - Fire Retardant Plywood

IS 5509 | E1 Grade Resin | HVRT Technology | 30 Year Warranty

Fill the form for Quick Enquiry

Got something on your mind? Reach out and let’s connect. We’re always here to listen, help, and make things happen.